Permit: T00PL01746

Parcel: 13219052C


Addresses:

2802 E OHIO ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/03/2000 PLUMBING - FINAL Approved
10/02/2000 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*
09/29/2000 PLUMBING - FINAL Partial Approval SEPTIC TANK OK TO COVER
I NEED TO SEE CONNECTION TO EXISTING
I NEED TO SEE EXISTING SEPTIC TANK PUMPED AND BROKEN BEFORE FILLING WITH AGGREGATE
I NEED TO SEE LEACH LEACH FIELD CONVERED WITH 2" AGGREGATE AND FILTER FOR DIRT
09/26/2000 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1. CLEAN OUTS SHALL BE MADE WITH WYE BRANCH FITTINGS
2. DRAIN OUTLET FROM SEPTIC TANK BACK PITCHED
3.. LEACH PIPING BACK PITCHED. HOW IS SEPTIC TO DRAIN?
4. AFTER CORRECTIONS MADE AND RE INSPECTED LEACH PIPING TO BE COVERED WITH 2" OF AGGREGATE AND FLU STRAW OR BLDG PAPER BEFORE NATURAL FILL