Permit: T00PL01595

Parcel: 119042460


Addresses:

225 W 44TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/27/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*
02/22/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) NO ONE HOME NO ACCESS INSIDE 2) ALL UNDER GROUND GAS PIPE MUST BE SCOTCH COAT TAPEING IS LIMITED TO FITTINGS AND SHORT SECTIONS OF PIPE MARRED BY TOOLS
3) T AND P DRAIN NEEDS A UNION 4) 1" CLEARANCE AROUND FLU PIPE AT COMBUSTABLE
08/29/2000 PLUMBING - FINAL Denied IVRS - Inspection 0999*
08/25/2000 PLUMBING - FINAL Denied A LICENSED CONTRACTOR MUST DO THIS WORK
ALL MAT'LS FROM 6" AFF AND BELOW MUST BE APPROVED MATERIALS AND ALL EXPOSED JOINTS TO BE FILED WRAPPED
WATER HEATER TO BE SET ON A CONCRETE PAD
T& P MUST EXTEND TO WITHIN 6" AFF
MINIMUM DEPTH FOR GAS LINE 12" VALVE FOR STOVE IN ON POSITION BUT LINE HOLDING PRESSURE HOW IS THIS POSSIBLE
THERE ARE NUMERALS OTHER CODES VIOLATIONS IN AND AROUND THIS AREA THAT NEED TO BE ADDRESSED HAVE LICENSED CONTRACTOR MAKE REPAIRS