Permit: T00PL01581

Parcel: 119041230


Addresses:

3731 S LIBERTY AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/03/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*
04/11/2001 PLUMBING - FINAL Denied 1. NEED COMBUSTION SUPPLY AND RELIEF OPENINGS IN DOOR OF WATER HEATER ENCLOSURE. 2. EXTEND T.P.R.V. DISCHARGE LINE DOWN TO BETWEEN 6" AND 24" ABOVE FLOOR LEVEL. CANNOT BE THREADED ON DISCHARGE END. 3. NEED PERMIT FOR SEWER/WASTE PIPING. 4. NEED APPROVED DRAWING FOR GAS PIPE SIZING.
08/29/2000 PLUMBING - FINAL Denied IVRS - Inspection 0999*
08/22/2000 PLUMBING - FINAL Denied NO ENCLOSURE FOR WATER HEATER
WATER HEATER FLUE PIPING NOT CONNECTED
BLACK IRON PIPE NOT ACCEPTABLE MATERIAL FOR WATER
T&P DOES NOT EXTEND TO WITHIN 6" AFF
WATER HEATER NOT SET ON CONCRETE PAD
I NEED TO SEE A DRAWING WITH THE GAS SIZING TO EACH APPLIANCE PER 94 UPC
THERE ARE SEVERAL PLUMBING ISSUES THAT NEED TO BE ADDRESSED INCLUDING
VENT PIPE FULL OF HOLES
ABS WASTE PIPING DUMPING ONTO BACK PROCH
THIS LIST MAY NOT INCLUDE ALL CODE VIOLATIONS AND CONTRACTOR IS RESPONSIBLE FOR PERMITS TO CORRECT UNSAFE OR UNACCEPTABLE CONDITIONS