Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2000 | PLUMBING - GAS PRESSURE TEST | Approved | ||
| 09/25/2000 | PLUMBING - GAS PRESSURE TEST | Partial Approval | TEST OK CORRECTIONS HAVE BEEN MADE AS PER LAST REQUEST. OK TO BACKFILL. GAS FOR POOL HEATER ONLY. EXISTING METER ON AT THIS TIME |
|
| 09/21/2000 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* PRESSURE TEST OK WILL NEED TO RETEST AFTER CORRECTIONS ARE MADE ALL GAS PIPING FROM 6" AFF AND BELOW SHALL BE PROTECTED WITH MACHINE APPLIED COATING WRAPPING WITH 10 MIL TAPE IS RESTRICTED TO THOSE FITTINGS AND SHORT SECTIONS WHERE THE FACTORY WRAP HAS BEEN DAMAGED OR NECESSARILY STRIPPED FOR THREADING. WRAPPED BLACK IRON PIPE IS NOT ACCEPTABLE |