Permit: T00PL01305

Parcel: 120083810


Addresses:

123 W MISSOURI ST

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/18/2000 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
NO PRESSURE TEST 10# FOR 15 MIN
NEW SOTCH COAT UNDERGROUND COVERED BEFORE INSPECTION
TAPING LIMITED TO SHORT SECTIONS DAMAGED BY WRENCHES, AND FITTINGS
NO BLACK PIPE UNDERGROUND AND SHALL BE KEPT AT LEAST 6" AFF.
NEED TO SEE GAS ISOMETRIC-WITH BTU EQUIVALENCY
THERE SEEMS TO BE QUITE A BIT OF PLUMBING ALREADY COMPLETED BUT NO EVIDENCE OF PLANS OR PERMIT