Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2000 | PLUMBING - GAS PRESSURE TEST | Approved | ||
| 07/21/2000 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* 1. MUST REMOVE UNIONS ON ROOF AND REPLACE WITH RIGHT AND LEFT HAND NIPPLES 2. MUST USE APPROVED TWO HOLE STRAPS ON GAS LINE |
|
| 07/20/2000 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* 1. GAS PIPE ON SIDE OF HOUSE NEEDS TO BE ANCHORED TO THE WALL 2. GAS PIPE ON ROOF IS NOT BLOCKED OR STRAPPED PROPERLY 3. ALL UNIONS IN GAS LINES MUST HAVE A SHUT OFF VALVE BEFORE THE UNION 4. NEED TO ACCESS INSIDE THE HOUSE TO SEE APPROVED GAS SHUT OFF VALVES AT EACH APPLIANCE |
|
| 07/19/2000 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* 1. MUST PROVIDE AIR PRESSURE TEST ON ENTIRE SYSTEM 10 LBS MIN |