Permit: T00PL01109

Parcel: 107030110


Addresses:

2033 W WATER ST

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
07/05/2000 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*
07/03/2000 PLUMBING - GAS PRESSURE TEST Denied 1. WATER HEATER HAS TRAP IN P&T DRAIN MUST PROVIDE DRAIN IN LINE AT LOWEST POINT
2. MUST HAVE 1" CLEARANCE AROUND DBL WALL FLU VENTS FOR FURNACE AND WATER HEATER
3. 3/4" GAS LINE IS TOO SMALL FOR BTU AND CFH DEMAND MUST BE 1" UP TO TEE AT WATER HEATER AND FURNACE ROOM TO DRYER ROOM
4. 3/4" GAS LINE UNDERGROUND HAS THREAD PROTECTOR. THIS COUPLING IS NOT APPROVED MATERIAL