Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 09/12/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
|
| 06/08/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Correction Required |
ADDTL COMMS - 1. NEED TO RELOCATE HOT WATER HEATER OUT OF BATHROOM NO HOT WATER HEATER ALLOW IN BATHROOM MOVE HEATER TO OUTSIDE STORAGE ROOM 2. GAS PIPING UNDERSIZE 1 REQUIRE UP TO GAS RANGE 3. NEED A.G.A. GAS VALVES ON ALL APPLIANCES 4. RUN 3/4 P&T DRAIN TO OUTSIDE AT HOT WATER HEATER 5. USE APPROVE DOUBLE WALL VENT ON HOT WATER HEATER 1 ABOVE COOLER 6. PROVIDE FRESH AIR OR STORAGE ROOM DOOR. FOR HOT WATER HEATER. |
| 06/08/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0000* |