Permit: T00PL00231

Parcel: 119211390


Addresses:

1639 W CIRCLE B DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
02/10/2000 PLUMBING - GAS PRESSURE TEST Approved
02/03/2000 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*
02/01/2000 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. REMOVE 3/4 UNION AND USE RIGHT AND LEFT HAND NIPPO WITH COUPLING 2. REMOVE 3 BLACK PIPE AND USE 3 GALV STOVE PIPE 3. RUN 3/4 P&T DRAIN LINE TO OUTSIDE 4. REMOVE DUCT TAPE ON VENT AND USE METAL SCREWS 5. 10 LBS TEST REQUIRE 6. ALL EXPOSE GAS PIPING SHALL BE 6 OR MORE ABOVE SLAB 7. CHECK FOR B.T.U. RATING ON ALL APPLIANCE FOR PIPE SIZE AND DISTANCE 8. CHECK OUTLET OF RANGE FOR SIZE
02/01/2000 PLUMBING - GAS PRESSURE TEST Denied DENIED