Permit: T00PL00010

Parcel: 123071200


Addresses:

2015 E HELEN ST

Inspection Status: Correction Required

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
01/14/2000 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. SOIL WATER TEST OK 2. HCS CONNECTION OK 3. OK TO BACKFILL TRENCH
01/13/2000 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. MUST SHADE BLDG SEWER BEFORE BACKFILL. SEE SECTION 315.4 UPC. SHADE PIPE UP TO TOP OF PIPE ONLY NO ROCKS 2. NOTE: BACKWATER VALVE IS QUESTIONABLE CHECK UPSTREAM MANHOLE HEIGHT, MUST BE 12 BELOW FINISH FLOOR LEVEL.
01/13/2000 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0000*
01/11/2000 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. WILL REQUIRE GRADE CLEAN OUT WHERE SEWER LINE EXCEEDS 135 DEGREE 2. RE TEST SYSTEM 3. EXPOSE HCS CONNECTION.
01/11/2000 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0000*