Inspection Status: Approved
Inspection History: MOBILE HOME UNDERGROUND GAS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2001 | MOBILE HOME UNDERGROUND GAS | Approved | IVRS - Inspection 0000* | |
| 01/16/2001 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* 1. UNDERGROUND PIPE MUST BE FACTORY COATED (GREEN OR YELLOW SCOTCH GAURD IS LEAST EXPENSIVE. 2. MOVE RISER SO IT IS NOT UNDER HOME 3. INSTALL A FLEX CONNECTOR FOR MANUFACTURED HOUSING NOT AN APPLIANCE CONNECTOR DO A PROPER PRESSURE TEST |
|
| 01/04/2001 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* | |
| 12/11/2000 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* INSTALL FLEX LINE AND SHUT OFF VALVE SHEETROCK GROUND FURNACE SHEET ROCK HOT WATER HEATER CLOSE 5/16" MIM SHEETROCK |