Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MOBILE HOME UNDERGROUND GAS
Permit Number - T00MH00462
Inspection Description - MOBILE HOME UNDERGROUND GAS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/13/2000 | MOBILE HOME UNDERGROUND GAS | Approved | IVRS - Inspection 0000* | |
10/04/2000 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* THIS MAKES 3 FAILED INSPECTION ON YOUR GAS AND 4 SEPERATE INSPECTIONS ON YOU HOME. YOU WILL BE ASSESSED ANOTHER INSPECTION FEE IF YOU CANNOT MAKE THE NECESSARY REPAIRS BEFORE MY NEXT INSPECTION |
|
09/29/2000 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* FLEX LINE ON WRONG SIDE OF VALVE AND UNION |
|
09/20/2000 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* PRESSURE TEST FAILED PRESSURE GAUGE SHOULD READ IN 1/10 LB INCREMENTS |
|
09/11/2000 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* NO GAS PRESSURE TEST FLEX LIVES INSIDE HOME TO CAPPED WITH VALVES TURNED ON FOR TEST |