Inspection History: MOBILE HOME SITE LOC./SET-UP

Permit Number - T00MH00388

Inspection Description - MOBILE HOME SITE LOC./SET-UP

Inspection Status - Approved

Date Description Inspector Results Comments
06/26/2001 MOBILE HOME SITE LOC./SET-UP Approved IVRS - Inspection 0000*
06/19/2001 MOBILE HOME SITE LOC./SET-UP Denied IVRS - Inspection 0925*REMOVE ALL SHIRTING AND INSTALL PIERS WHERE REQUIRED 2' FROM EACH END AND EVERY 6' MIN. UNDER THE FRAMES.ALSO INSTALL OUTER PERIMETER PIERS UNDER ALL DOORS AND WINDOWS LARGER THAN 4 ".
06/01/2001 MOBILE HOME SITE LOC./SET-UP Not ready for Inspection IVRS - Inspection 0000*AZ BOX FOR COOLERS.DEAD FRONT ON SERVICE SUB PANEL.PERMIT AND INSPECTION FOR MAIN SERVICE.PERMANENT ADDRESS LABEL ON SERVICE.USE COMBINATION WYE FITTING FOR DRAIN CONNECTION.FIX LEAK ON WATER HEATER.INSTALL DISCHARGE PIPE ON WATER HEATER PRESSURE VALVE (C.P.V.C OR GALVAMIZED PIPE).REMOVE SKIRTING ON ONE SIDE FOR INSPECTION.INSTALL BACKFLOW DEVICES ON HOSE BIBS.