Permit: T00MH00077

Parcel: 107051080


Addresses:

2928 N 15TH AV #08


Inspection Status: Correction Required

Inspection History: MOBILE HOME PLUMBING

Permit Number - T00MH00077

Inspection Description - MOBILE HOME PLUMBING

Inspection Status - Correction Required

Date Description Inspector Results Comments
03/01/2000 MOBILE HOME PLUMBING Correction Required ADDTL COMMS - 1. NEED SHUT OFF VALVE ON SUPPLY LINE TO WATER HEATER. 2. NEED VENT CONNECTOR ON HEATER 3. NEED DISCHARGE LINE ON T.P.R.V 4. NEED ENCLOSURE FOR W.H. 5. EXTEND W.H. VENT PIPE ABOVE UNIT
03/01/2000 MOBILE HOME PLUMBING Partial Approval IVRS - Inspection 0000*
02/28/2000 MOBILE HOME PLUMBING Correction Required ADDTL COMMS - PLEASE SEE LAST INSPECTION
02/28/2000 MOBILE HOME PLUMBING Not ready for Inspection NOT READY FOR INSPECTION
02/22/2000 MOBILE HOME PLUMBING Correction Required ADDTL COMMS - 1. GAS VALVE LEAKING INSIDE FOR THE STOVE NEEDS REPLACED AND GAS PRESSURE TEST 2. HOT WATER HEATER NEED A SAFETY VALVE INSTALLED 3. NEED SHUT OFF VALVES INSTALLED FOR THE SINK LAV, TOILET 4. HOT WATER HEATER NEEDS A VENT CAP INSTALLED 5. SEWER LINE LEAKING NEEDS REPAIRED CALL FOR REINSPECTION
02/22/2000 MOBILE HOME PLUMBING Denied DENIED