Permit: T00ME00984

Parcel: 122140140


Addresses:

3101 E FAIRMOUNT ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/06/2000 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
09/26/2000 MECHANICAL - FINAL Denied IVRS - Inspection 0999*
1. FURNACE DOES NOT HAVE ADEQUATE COMBUSTION AIR. NEED TO HAVE HIGH AND LOW
2. FURNACE VENT NEEDS 1" CLEARANCE FROM COMBUSTIBLES WHERE PENETRATING CEILING.
3. RAISE FURNACE VENT 1' ABOVE COOLER
4. GAS LINE NEEDS PRESSURE TEST AND INSPECTION
5. RECOMMEND INSTALLING A PROTECTIVE SCREEN OVER HEATER VENT IN REAR HOUSE
NEED TO SEE YOU MUST HAVE A PLUMBING PERMIT AND INSPECTION
6. HEATER IN REAR HOUSE NEEDS A PERMIT AND INSPECTION