Permit: T00ME00495

Parcel: 126110010


Addresses:

4356 E WHITMAN ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/18/2001 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
04/11/2001 MECHANICAL - FINAL Denied IVRS - Inspection 0999* YOU CAN NOT TERMINATE CONDENSATE INTO A VENT SMALLER THAN 2"
CORRECT AND RE CALL FOR FINAL INSP.
04/05/2001 MECHANICAL - FINAL Denied IVRS - Inspection 0999* 1) CANNOT TERMINATE CONDENSATE INTO A WASTE VENT SMALLER THAN 2". USE A 3/4" TEE WHEN TERMINATING OVER THE TOP OF THE VENT, NOT AN ELBOW. 2) PAINT EXPOSED PVC WITH LATEX PAINT 3) GAS FLEX CONNECTOR NOT ADEQUATE SIZE FOR 81,000 BTU. SEE TABLE 3-D-2 1994 UMC FOR PROPER SIZING