Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/22/2000 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* OK TO CLEAR OWNER RECEIVED PERMISSION FROM TEP TO CUT SEAL ON BREAKER COMPARTMENT TO TURN BREAKERS ON APPARENTLY METER WAS NOT BOOTED TO KILL POWER METER HAS LOCKING RING INSTALLED OWNER HAS COMPLIED WITH WRITE UP |
|
| 11/21/2000 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection 0000* CONTACT TEP AND ASK TO BOOT METER TO ALLOW WORK TO BE DONE ON BREAKER SECTION OF SERVICE SAFETY |
|
| 11/16/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245* WIRING EXPOSED OUTSIDE SOUTH END OF DWELLING MUST BE ABANDONED, OR CAPPED OFF AND BLANK COVER INSTALLED BY WINDOW, EXPOSED DETERIORATED ROMEX MUST BE REMOVED OR INSTALLED IN CONDUIT FOR SECURITY LIGHTING INSTALL MIDWEST BOX FOR COOLER CLEAN UP EXPOOSED WIRING ON ROOF LIGHT FIXTURES UNDER EAST ROOF OVER HANG NEED TO BE MOUNTED ON APPROVED J-BOXES WITH TERMINATIONS IN J-BOXES REPLACE 3 WIRE OUTLETS ON 2 WIRE CIRUCITS, BACK TO 2 WIRE OUTLETS OR INSTALL A GFCI RECEPTACLE A HEAD OF CIRCUIT INSTALL PERMANENT MOUNTED HEATING APPLIANCES IN NON HEATED ROOMS ROMEX WIRING OUTSIDE WEST OF BLD MUST BE IN CONDUIT(EXPOSED) |