Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* EXPOSED ROMEX FILL ALL UNUSED OPENINGS AT PANEL MISSING FACE PLATES OPEN BOX WITH ROMEX NEED LIGHTING AT FRONT ENTRANCE NO APPERANT HEATING NEED PERMANTLY ATTACHED HEATING UNIT NEED TO SEE CONNECTIONS FOR COOLER SUBJECT TO BUILDING INSPECTION |
|
| 12/12/2000 | ELECTRIC - FINAL | Denied | NEED 1 HR GENERAL REPAIR PERMIT TO REPAIR DAMAGED DRYWALL THUR OUT WILL NEED INSPECTIONS WHEN WORK DONE WILL NEED LICENSED CONTRACTOR TO DO WORK |
|
| 12/11/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* CAN NOT IDENTIFY WHICH BUILDING SERVICE THIS IS EXPOSED CONDUTORS THROUGH OUT UNAPPROVED CORD THRU WALL TO PANEL UNPROTECTED AND EXPOSED ROMEX THROUGH OUT FIXTURES TO BE ATTACHED TO APPORVED JUNCTION BOXES USE APPROVED WIRING METHODS AND EQUIPMENT FOR COOLER USE MANUFACTURE APPROVED CORDS WITH FIXTURE NOT SPLICED CORD FILL ALL UNUSED OPERNING IN PANEL NEED ALL SCREWS FOR JUNCTION BOX COOLER NEED BUILIDNG INSPECTOR TO CHECK STRUCTURE NEED 1 HRS GENERAL REPAIR PERMIT TO REPAIR |