Permit: T00EL02611

Parcel: 12513002B


Addresses:

3238 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/21/2000 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
11/20/2000 ELECTRIC - FINAL Denied IVRS - Inspection 0999*
1999 NEC SECTION 600-2B- TRANSFORMERS WITH ISOLATED SECONDARY AND A MAX OPEN CIRCUIT VOLTAGE OF 7500 VOLTS OR MORE
SHALL HAVE SECONDARY CIRCUIT GROUND PROTECTION
GTO IN ENCLOSURE TO BE SPACED 1 1/2" FROM OTHER CONDUCTORS AND ALL OTHER OBJECTS (ENCLOSURE)
SIGN DISCONNECT BOX TO BE GROUNDED AND PRIMARY SUPPLY CONDUCTORS TO GO PHYSICALLY PROTECTED IN SWITCH BOX
VERIFY SIGN CIRCUIT IN PANEL MARKED SIGN