Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/27/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/22/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245* 1) MC CABLE NOT TERMINATED PROPERLY IN DISCONNECT SWITCH 370-17 NEC 2) SUPPORT MC ABOVE CEILING PER NEC 334-10,300-11 DO NOT USE GRID WIRES TO SUPPORT MC CABLE 3) DEVICE BOXES UNDER TABLES IN THEATER NEED TO BE GROUNDED |