Permit: T00EL02416

Parcel: 12106271A


Addresses:

5829 E LEE ST

Inspection Status: Partial Approval

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
02/20/2001 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection 0000* INSTALL BRACE ON RISER PROPERLY
12/22/2000 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0245*
BOND GAS PIPING SYSTEM
GROUND BUSHINGS REQUIRED ON CLOSE NIPPLES AT LB FITTING IN PANEL(AT CONCENTRICS WITH RW'S)
PERMANENT ADDRESS TAG REQUIRED NO MARKER PEN NO SELF ADHESIVE NUMBERS 230-70 NEC
USE 1/4" MIN. ANCHOR BOLTS TO SUPPORT RISER,
NEED VERIFICATION OF C-11 LICENSED CONTRACTOR