Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/27/2000 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
OK TO CLEAR
10/17/2000 ELECTRIC - FINAL Denied IVRS - Inspection 0245*
SMOKE DETECTORS INSTALLED TO LOW, SHOULD BE BETWEEN 6" TO 12" DOWN FROM CEILING. 2' OR MORE AWAY FROM AC REGISTER. INSTALL GFCI RECEPTACLE FOR WASHER, RECEPTACLE INSTALLED IS UNGROUNDED. MIDWEST COOLER BOX NEED TO BE RE ATTACHED (LAYING ON SIDE ON ROOF)
INSTALL LB COVER BY SERVICE
10/03/2000 ELECTRIC - FINAL Denied IVRS - Inspection 0245*
DERIVE GROUND FROM SOURCE OF POWER AT SERVICE. GROUND FOR WASHER RECEPTACLE IS CONNECTED TO WATER PIPING (NOT ALLOWED)
INSTALL SMOKE DETECTORS IN BEDROOMS AND HALLWAY
REMOVE ABANDONED WIRING (CAR PORT)
WIRING BELOW CEILINGS ON WALLS MUST BE IN CONDUIT BELOW KITCHEN SINK BACK PORCH
REPAIR DAMAGED LIGHT FIXTURES, BATHROOM KITCHEN
CLOSET LIGHT MUST HAVE COVER OVER LAMP