Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2000 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* OK TO CLEAR |
|
| 10/17/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245* SMOKE DETECTORS INSTALLED TO LOW, SHOULD BE BETWEEN 6" TO 12" DOWN FROM CEILING. 2' OR MORE AWAY FROM AC REGISTER. INSTALL GFCI RECEPTACLE FOR WASHER, RECEPTACLE INSTALLED IS UNGROUNDED. MIDWEST COOLER BOX NEED TO BE RE ATTACHED (LAYING ON SIDE ON ROOF) INSTALL LB COVER BY SERVICE |
|
| 10/03/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245* DERIVE GROUND FROM SOURCE OF POWER AT SERVICE. GROUND FOR WASHER RECEPTACLE IS CONNECTED TO WATER PIPING (NOT ALLOWED) INSTALL SMOKE DETECTORS IN BEDROOMS AND HALLWAY REMOVE ABANDONED WIRING (CAR PORT) WIRING BELOW CEILINGS ON WALLS MUST BE IN CONDUIT BELOW KITCHEN SINK BACK PORCH REPAIR DAMAGED LIGHT FIXTURES, BATHROOM KITCHEN CLOSET LIGHT MUST HAVE COVER OVER LAMP |