Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/03/2000 | ELECTRIC - SERVICE UPGRADE | Approved | ||
| 10/12/2000 | ELECTRIC - SERVICE UPGRADE | Partial Approval | 10/13/00 OK TO CLEAR | |
| 09/11/2000 | ELECTRIC - SERVICE UPGRADE | Denied | BOND GAS STRAP GROUND WIRE TO WALL SIZE BONDING JUMPER ACCORDINGLY TO CODE NEED LOCKNUT AND BOTH REDUCING WASHERS NEED 2 SUPPORTS ON RISER BELOW ROOF WITH ANCHOR NOT NAILS SUPPORT1" CONDUIT WITHIN 3' OF FITTINGS AT PANEL NEED SWIMMING POOL MOVED TO MEET CLEARENCES PER CODE NEED TO SEE CROSSOVER CONNECTIONS AFTER CLEARANCE PLEASE LEAVE OLD INSPECTION REPORTS OUTSIDE |
|
| 09/08/2000 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection 0999* 2 SUPPORTS REQUIRED ON RISER BELOW ROOF LINE INSTALL ROOF JACK ELECTRICAL LINES OVER POOL NEED TO BE 25' ABOVE WATER OR MOVE POOL USE ROMEX CONNECTION ON GROUND WIRES AT BOTTOM OF SERVICE NEED TO USE A GROUNDING BUSHING AT ENTRY TO CON ON 1" LB BECAUSE YOU GO THUR CONCENTRICS USE CORRECT BREAKERS MUST USE A PERMANENT LABEL ON SERVICE NO PEN STRAP #4 TO WALL DRIVE RODS TO BELOW GRADE AND BURY GROUND WIRE |