Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00EL01763

Parcel: 120084110


Addresses:

167 W TENNESSEE ST

Inspection Status: Denied

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
07/28/2000 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999$
NO INSPECTION
I'VE REQUESTED THE NAME AND NUMBER OF THE LICENSED CONTRACTOR BEFORE ANY INSPECTION SEE ITEM # 5
07/24/2000 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection 0000*
1. USE #4 BARE COPPER FOR GROUNDING
2. NEED GAS BOND
3. NEED ADDRESS
4. STRAP GROUND WIRE
5. CALL 971-5550 X 136 ELECT CONTRATOR BEFORE NEXT INSPECTION