Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 02/14/2001 | ELECTRIC - FINAL | Denied | BUSHING IN PANEL FOR NEW CIRCUIT REQUIRED | |
| 01/17/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000* #1 ITEM OF LIST OF 07-10-2000 NOT CORRECTED. NEW ROMEX IN PANEL NEEDS TO GO THUR A PLASTIC BUSHING |
|
| 07/10/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1. AT PANEL BOX NEED A FITTING WHERE NEW ROMEX ENTERS A FITTING IS REQUIRED TO INSULATE WIRE 2. OLD FPE CIRCUIT BREAKERS INSTALLED 1-20 AMP 1-15 AMP 3. SPLICE IN ATTIC IS REQUIRED TO BE IN A JUNCTION BOX 4. RECEPTACLE IN BATHROOM IS REQUIRED TO GFI PROTECTED ONCE CHANGED OUT |