Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/26/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* OK TO CLEAR 3 &4 #1&2 RECONNECT ALREADY RECONNECTED |
|
| 01/21/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* NO MESSAGE ON IVR NOTED THAT THERE WAS A CALL FOR ONE #4 USE APPROVED WIRING METHOD FOR HEATER #3 USE APPROVED WIRING METHOD FOR HEATER COMPLETE PREVIOUS INSPECTION REPORTS |
|
| 10/27/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* | |
| 10/24/2000 | ELECTRIC - FINAL | Denied | 10/24/00 DISCONNECT #3 HAS A 1" OPEN HOLE AT BOTTOM SEAL IT OFF BASE BOADR HEATER NEED TO HAVE CORD REMOVED AND HARDWIRED ALL THE WAY INTO J-BOX WITH #12 WIRE ALL THE WAY |
|
| 08/24/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* | |
| 07/19/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1. NEED HEATING 2. SUPPORT CONDUTORS AT SOB PANEL #4 3. COVER NEED TO BE WEATHER PROOF 410-57 |
|
| 07/14/2000 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1. NEED ATTACHED HEATING UNIT 2. BOXES OUTSIDE NEED TO BE WEATHER PROOF NEED ATTACHED HEATING UNIT 3. NEED ATTACHED HEATING UNIT 4. NEED ATTACHED HEATING UNIT SUPPORT CABLES AT SUB PANEL NEED CORRECT CONNECTIONS FOR GROUNDING ELECTRODE CONDUTORS BOND ALL GAS SERVICES NOT JUST 1 UNIT SUPPORT CONDUCTOR AND CONDUIT FROM SERVICES PROTECT SERVICE CONDUCTORS #2 NEED PERMANENT METAL ADDRESS LABELS |