Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2000 | ELECTRIC - RECONNECT | Approved | ||
| 07/21/2000 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0920* LOCKED ALL 3 DOORS |
|
| 06/13/2000 | ELECTRIC - RECONNECT | Correction Required | ADDTL COMMS - CORRECT ALL ITEMS FROM INSPECTION DONE ON 04/24/00. ALONG WITH 13. OPEN SPLICE IN STORAGE ROOM IS NOT ALLOWED 14. FRONT DOOR FIXTURE IS DAMAGED 15. LOCKED CORRECT ALL ITEMS PRIOR TO NEXT INSPECTION 1 THUR 15 | |
| 06/13/2000 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999* | |
| 04/24/2000 | ELECTRIC - RECONNECT | Correction Required | ADDTL COMMS - 1. SECURE LOOSE NM CABLE AT CARPORT 2. PROPERLY WIRE FLOR. CARPORT FIXTURES 3. REPLACE DAMAGED RECEPTACLES 4. INSTALL MISSING FIXTURES, HOODS, SMOKE DETECTORS PLATES ETC 5. C FANS NEED 3 WIRE CORD OR REMOVE 6. CONDUIT APART 7. CONDUIT LOOSE 8. OUTDOOR RECEPT TO BE GFCI TYPE 9. SECURE EMT CONDUIT PER NEC 10. NM CABLE TO BE PHYSICALLY PROTECTED 11. FLOR, FIXTURES AT BACK PORCH ARE NOT PROPERLY WIRED FROM WALL FIXTURES 12. ALL MIN HOUSING REQUIREMENTS MUST BE MET SUCH AS A WORKING TOILET SINK HEAT COOLING KITCHEN | |
| 04/24/2000 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999* |