Permit: T00EL00635

Parcel: 135061910

Inspection Status: Correction Required

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
04/10/2000 ELECTRIC - SERVICE UPGRADE Correction Required ADDTL COMMS - 1. INSTALL GROUNDING ELECTRODE IN A NEAT AND WORKMANLIKE MANNER (110-12 N.E.C.) 2. INSTALL RISER 3. SEAL UNUSED OPENINGS 4. BONDING BUSHING REQD ON RISER 5. E.M.T. CONNECTORS NOT TO BE USED RIGID USE THREADED RIGID OR IMC NIPPLE 6. CONTRACTOR TO CALL ME AND MAKE APPOINTMENTS C-11 LIC IS REQD BY STATE OF AZ. 7. PERMIT REQUIRED BY LIC CONTRACTOR 8. SPLICE AND AT GROUND ROD IS NOT ACCEPTABLE OTHER ISSUES TO BE ADDRESSED BETWEEN ME AND THE ELEC CONTRACTOR REINSP FEE DUE PRIOR TO 3RD INSP.
04/10/2000 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999$
03/28/2000 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection 0000*
03/27/2000 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection 0000*
03/21/2000 ELECTRIC - SERVICE UPGRADE Correction Required ADDTL COMMS - 1. INSTALL GROUNDING ELECTRODE CONDUCTOR TO SERVICE (#4) FINISH GROUNDING 2. INSTALL #4 WATERBOND AND GAS 3. INSTALL 2 1/2 RISER W/LOCKNUTS AND BONDING BUSHING 4. ROBERT HUTSONS C-11 LIC IS NEEDED 5. INSTALL #8 COPPER FOR 50 AMP CIRCUIT BREAKER (CANNOT PARALLEL #12) 6. USE CONNECTORS AT J-BOX N.M. 7. TEMP SPLICE OF NEUTRAL IS REDICULOUS PLEASE REPAIR A.S.A.P USING A CODE APPROVED METHOD. 8. OPEN SPLICE IN LAUNDRY ROOM IS NOT ACCEPTABLE PLEASE CALL ME TOMMOROW 7:30-8:00 AM AT 791-5550 X136
03/21/2000 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999*