Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
02/01/2000 ELECTRIC - SERVICE UPGRADE Correction Required ADDTL COMMS - DENIED AS REQUESTED OWNER NEED TO CALL OFFICE AND LEAVE NAME AND NUMBER OF REQUIRED C-11 ELECTRICAL CONTRACTOR
02/01/2000 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999$
01/13/2000 ELECTRIC - SERVICE UPGRADE Correction Required ADDTL COMMS - 1. NEED 2 DRIVER GROUNDS FOR SERVICE PANEL 2. RANGE RECPTACLE REQUIRES 4 PRONG OUTLET 3. CONNECT CONDUCTORS TO NEW PANEL 4. WATER HEATER VENT NEEDS TO BE SECURED B VENT REQUIRES 1 CLEARANCE TO COMBUSTIBLES. SINGLE WALL CONNECTOR NEEDS 6 CLEARANCE TO COMBUSTIBLES.
01/13/2000 ELECTRIC - SERVICE UPGRADE Denied DENIED