Permit: T00CM06225


Addresses:

3007 N GAIA PL

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/31/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
05/30/2002 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) DISCONNECTING MEANS TO BE WITHIN SITE OF OUTSIDE. A/C UNIT.
05/29/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0999*1.) PLEASE CORRECTLY WIRE A/C DISCONNECT ON CASITA 2.) WE HAVE LOOSE SEAL TITE FITTINGS A/C ON CASITA. 3.) OUTLET RECPETCALES SPACING REQUIRED AS PER CODE 210-52. 4.) AN EXTENDER RING IS NEEDED WHERE DEVICE IS OVER 1/8" PAST BOX 5.) RECEPTICAL TO HAVE ONLY ONE WIRE UNDER GROUND SCREW AND DEVICE SCREWS SHOULD BE SCREWED IN TO PREVENT CONTACT WITH METAL BOXES. 6.) PLEASE CLEAN BUSS OF FORIGEN MATERAL AT SUB PANEL..
05/24/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*
05/22/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0999*AC UNIT NOT IN, NEED TO COVER ELECT TRENCH, LIGHT UNDER KIT CABINET MISSING HAVE ELECTRICIAN CHECK UNIT OUT FOR FINAL PRIOR TO CALLING HAVE ALL ITEMS WORKING FOR TESTING.
05/17/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*