Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM06221

Parcel: 12309019C


Addresses:

1360 N STEWART AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/17/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/31/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) BUILD UP STUDS AT HEADERS, CORNERS AND POST ARE NOT BUILT OR FASTENED PER IRC, BUILD TO CODE OR PROVIDE CITY APPROVED ENGINEERINGS FOR SCREWS/BUILD UP OR HAVE AND BUILD TO LIGHT WEIGHT STEEL FRAME CONSTRUCTION STANDARDS 2) PROVIDE CITY OF TUCSON APPROVAL OF PLAN REVISION 3) PROVIDE ACCESS TO JACCUZI HEAD OFF ACCESS 4) PROVIDE PROPER CHAFE PROTECTION FOR PEX 5) SCREW PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
08/21/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) L HEADERS NOT SCREWED TO TOP TRACK PER 18/47 12" ON CENTER 2) PROVIDE TRUSS DESIGN FOR GARAGE HEADER-GIRDER TRUSS 3) TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON 4) NORTHEAST SHEARWALL 1 MUST BE 7'-11" NOW 5'-0" 5) SOUTHWEST SHEARWALL MUST BE 12'-0" NOW 6'-0"
6) TRACK HILT-PINS REQUIRED AT 12" ON CENTER SEE 14/6 7) PORCH POST TO BEAM CONNECTION NOT MADE SEE 2/5 8) PROVIDE DETAIL OF 6 X 12 BEAM CONNECTION TO STEEL STUD WALL 9) OK-TO DRY IN ROOF ONLY
08/15/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NEED ENGINEERED STEEL PACKET ON SITE UNABLE TO DETERMINE REQUIRED SCREW PATTERN AT L HEADERS 2) COMPLY W/DETAIL 7 SHEET 6 FOR TOP 3) ENGINEERED SCREW SCH FOR ROOF SHEATHIN REQUIRED