Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T00CM06179
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
03/19/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. ALUMINUM AND COPPER WIRES NOT PERMITTED UNDER SAME LUG SCREW. 2. ANTI-OX COMPOUND REQ'D ON ALUMINUM WIRE TERMINATIONS. 3. PAINT PLUMBING VENTS THROUGH ROOF. 4. VENT FAN IN MASTER WC NOT INSTALLED. 5. GFCI LEFT OF RANGE WON'T RIP WITH TESTER 6. PROVIDE LADDER TO ACCESS ATTIC. |