Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/26/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/22/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE FHA STRAP WITH 6 16D NAILS BOTH PLATES AT WATER MAIN AND CONDENSATE LINES. SEE UBC SEC. 2311.3. 2. PROVIDE DETAIL 6/SD2. 3. NEED TWO ANCHOR BOLTS AT SHEARWALLS. 4. DETAIL 13/SD2 DIAGNOL BRACES NOT COMPLETE NEED 6' 2X. 5. SECURE PEX LINES 4' O.C. 6. FHA STRAPS MISSING NAILS AT REFRIGERANT LINE. 7. SECURE BACK OF TUB VALVES. 8. UTR 90 DEGREE NOT SUPPORTED OR STRAPPED. 9. SMOKE DETECTOR NOT INSTALLED AS PER PLAN LOCATION. |