Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/26/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 02/22/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. SECURE ALL DOUBLE TOP PLATES NOT CABIN TIED. 2. #3 SHEARWALL SECOND FLOOR NOT INSTALLED AS PER PLAN. 3. HOLDOWNS NEED TO BE INSTALLED TO FULL HEIGHT DBL STUDS. 4. DETAIL 3/SD3 NOT INSTALLED AT GARAGE FRONT STRAP AND TRIPPLE KINGS. 5. JACK TRUSSES FRONT GARAGE NAILED THRU BACK SEE DETAIL 7/SD2 FOR CORRECT APPLICATION. 6. DETAIL 6/SD1 NOT COMPLETE AT FRONT COLUMNS. 7. PROVIDE 1/8 INCH GAP AT OSB PANEL ENDS AND EDGES. |