Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T00CM06158
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/20/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1)WATTS 007 #26486-FOR WATER SUPPLIED KITCHEN APPLIANCES.2)OK FOR C OF O PENDING VERTIFICATIONOF CERTICATION OF BACKFLOW PREVENTERS. |
|
| 06/19/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1)ALL CORRECTION MADE OK EXCEPT COFFEE MAKERS.2)AFTER READING INSTALLATION MANUAL AND EXAMING COFFEE BREWER, I OBSURRED THE SUBMERGED INLET TO THE RESERVOIR.THERE IS NO AIR GAP, ONLY AN AIR BREAK.PORTABLE WATER NEEDS PROTECTION. | |
| 06/18/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1)NO CHARGE FROM LAST INSPECTION.2)SEE NOTES FROM 06 06 01 AND COMPLY.3)ALL KITCHEN EQUIPMENT USING POTABLE WATER AND HAVING A SUBMERGED INLET REQUIRE BACKFLOW PROTECTION.4)ALL SODA FOUNTAIN DISPENSERS USING A CARBONATOR REQUIRE RPBP.5)CONTRACTOR TO PAY RE-INSPECTION FEE. | |
| 06/17/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* | |
| 06/15/2001 | PLUMBING - FINAL | Denied | 1. ALL WATER SUPPLIED FOUNTAIN DISPENSORS, COFFEE MAKERS, ICED TEA MAKERS ETC SHALL HAVE PRIMARY BACKFLOW PROTECTION DEVICES INSTALLED. 2.) KITCHEN EQUIPMENT DRAINS (INDIRECT) SHALL HAVE A MINIMUM 1" AIR GAP 3.) INDIRECT WASTER PIPING AND PRBP DRAINS SHALL BE SUPPORTED AND BRACED |
|
| 06/06/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1)PLEASE REVIEW REQUIREMENTS FOR INDIRECT WASTE PIPING INCLUDING AIR GAP REQUIREMENTS.2)ALL OVERHEAD PIPING CONCEALED.3)WATER GROPS FOR MAKER DO NOT INCLUDE BACK FLOW PROTECTION. |