Permit: T00CM06142

Parcel: 125021260


Addresses:

3034 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/12/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/09/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. RAFTERS CANNOT BEAR DIRECTLY ON OLD ROOF SHEATHING YOU MUST INSTALL A 2X SLEEPER THE WIDTH OF DIAGONAL CUT. 2. PROVIDE C.O.T. APPROVED DETAIL OF RIDGE BEAM CONNECTION OF CANTILEVER RAFTER TO CONNECTING WEST SIDE RAFTER. THIS CONSTRUCTION WOULD NORMALLY REQUIRE COLLAR TIES-ALSO ADDRESS CLIPPING. 3. HTT16 HOLD DOWNS MUST BE ATTACHED TO FULL LENGTH DOUBLE STUDS CLIP STUDS TO HEADER AND RAFTERS. 4. CLIP INTERIOR BEARING WALL AT 32: O.C. AND ALL RAFTERS. 5. MAX ALLOWED NAIL SPACING ROOF SHEATHING ENDS AND EDGES 6" O.C.