Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/13/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/08/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. RERUN ELECTRIC WIRE AT KITCHEN DOOR HEADER. 2. DO #6/STRAP BLOCKS CUT FOR DRYER VENT IN LOWER FURNACE CLOSET.. |
| 03/07/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/RE-PRESSURIZE FOR GAS TEST WHEN CHANGES COMPLETED. |
| 03/05/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. STRAP BLOCKS CUT FOR DRYER VENT IN LOWER FURNACE CLOSET. 2. DUCT AND PLUMBING INSTALLATION INCOMPLETE AT KITCHEN SOFFIT-INCOMPLETE FROM REPAIRS. |
| 03/01/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 02/27/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. STRAP HORIZONTAL GAS PIPE IN GARAGE AND KITCHEN AND SOFFIT 1ST FLOOR BATH. 2. BRACKET BOLTS MISSING ON GARAGE GLUELAMS. 3. GARAGE 6 X 6 FLOOR BRACKET NOT NAILED. 4. WRAP INTERIOR GARAGE WALL 6 X 6 WITH TAR PAPER AT BASE. 5. SHIM CANTILEVER STUDS AND HEARDERS WHERE NEEDED MANY. 6. STRAP BLOCKS CUT FOR DRYER VENT IN LOWER FURNACE CLOSET. 7. NAIL OFF ASU JACK TRUSS BRACKET IN DEN. 8. NAIL OFF JACK TRUSS BRACKET IN KITCHEN. |