Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/09/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 02/07/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/#'S 2 AND 5 NOT CORRECTED. |
| 02/05/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. MECHANICAL FRESH AIR ROOF DUCT, IN MASTER BED ROOF, MUST BE 10' AWAY FROM PLUMBING VENT. 2. STRAP CUT DOUBLE TOP PLATE OVER GARAGE PEDESTRIAN DOOR. 3. NAIL GARAGE FRONT HOLDOWN. 4. NEED STUD CLIPS AT FRONT WINDOW. 5. STRAP FRONT WINDOW, NON-CABIN TIED TOP PLATE. 7. FIRE BLOCK FRONT WINDOW BAY. 8. STRAP FRONT WINDOW HEADER. |