Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM06129
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/28/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/23/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. HANGERS NOT NAILED CHECK ALL. 2. VENT FOR WATER CLOSET SHOULD BE ABOVE CENTER OF DRAIN. 3. VENT FOR BATH EXHAUST NOT CONNECTED. 4. SWITCH FOR ATTIC LIGHT TO FAR FROM ACCESS. 5. SUPPORT MICRO LAM AT GARAGE NORTH WALL. | |
02/20/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. NEED SUPPORT AT ENTRANCE BEAM (GARAGE SIDE) AND F/B NEXT TO IT. 2. CHECK FOR MISSING POSTS. 3. HANGERS AT HIPS NOT NAILED-STOPPED INSP. SUPER NEEDS TO WALK JOB. 4. ATTIC LIGHT SWITCH. |