Permit: T00CM06126

Parcel: 116193570


Addresses:

420 N BONITA AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T00CM06126

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/21/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*PLEASE NOTE CORRECTIONS HAVE BEEN MADE. FINAL OK S.T.O.I. BACKFLOW HAVE BEEN CERTIFIED.
11/20/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*R-1 OF P-1 PROVIDE 30" CLEAR FLOOR SPACE AT UR. PROVIDE TESTING ON BACK FLOW DEVICE INSIDE BLDG.
11/18/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) REQ'D 15" FROM CENTER TO SIDEWALL ON HANDICAPPED URINAL 17" MAX AFF. FOR HANDICAPPED URINAL 2.) EXPANSION TANK TO BE SUPPORT 3.) OK FOR GAS SUBJECT TO MECHANICAL INSPECTORS.