Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/21/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* INSULATION MUST BE INSTALLED BEHIND TUBS. |
| 05/16/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 05/15/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*1.) MISSING DRAFT STOP @ SOFFITS 2.) BEARING HEADERS OF 1ST FLOOR ARE UP TO 1/4" ABOVE TRIMMERS. 3.) MISSING MIS INSTALLED OR DAMAGED HORIZONTAL AND VERTICAL DRAFT STOP THROUGOUT 1ST FLOOR. 4.) DAMAGED, MISSING AND MIS-INSTALLED DRAFT STOP ON 2ND FLOOR. 5.) OVERSPANNED VERTICAL STUDS IN SOME BEARING PARTITION AND SOME INTERIOR PARTITIONS. PLANS ASK FOR 16" BEARING 24" OR NON BEARING. |