Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM06088
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/21/2002 | FRAMING | Approved | IVRS - Inspection 0000* INSULATION MUST BE INSTALLED BEHIND TUBS. | |
05/16/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
05/15/2002 | FRAMING | Denied | IVRS - Inspection 0999*1.) MISSING DRAFT STOP @ SOFFITS 2.) BEARING HEADERS OF 1ST FLOOR ARE UP TO 1/4" ABOVE TRIMMERS. 3.) MISSING MIS INSTALLED OR DAMAGED HORIZONTAL AND VERTICAL DRAFT STOP THROUGOUT 1ST FLOOR. 4.) DAMAGED, MISSING AND MIS-INSTALLED DRAFT STOP ON 2ND FLOOR. 5.) OVERSPANNED VERTICAL STUDS IN SOME BEARING PARTITION AND SOME INTERIOR PARTITIONS. PLANS ASK FOR 16" BEARING 24" OR NON BEARING. |