Inspection History: FRAMING

Permit Number - T00CM06051

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/20/2001 FRAMING Approved IVRS - Inspection 0000*
03/19/2001 FRAMING Denied IVRS - Inspection 0999*/1. SHEAR WALLS #3 REQUIRE A.B. AT 48" OC. AND BLOCKING AT TOP CONCERNED AREAS. 2. SW 3 BY FIREPLACE REQUIRES STUDS AT 16"O.C. AND A.B.'S. 3. FIRE PLACE HAS COMBUSTIBLE OSB USE CEMENT BOARD. 4. PEX NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS 5. WIRES IN BATH LIGHT WELL. 6. NO WATER PRESSURE TEST ON PEX. 7. WIRES CANNOT BE EDGE NAILED (WEST OF LAUNDRY)
03/13/2001 FRAMING Denied IVRS - Inspection 0999*/1. MISSSING ANCHOR BOLTS ON BOTTOM PLATES. 2. NO TEST ON PLUMBING. 3. LIGHT FIXTURE IN BATHROOM NOT PROPERLY INSTALLED.