Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM06051
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/19/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. SHEAR WALLS #3 REQUIRE A.B. AT 48" OC. AND BLOCKING AT TOP CONCERNED AREAS. 2. SW 3 BY FIREPLACE REQUIRES STUDS AT 16"O.C. AND A.B.'S. 3. FIRE PLACE HAS COMBUSTIBLE OSB USE CEMENT BOARD. 4. PEX NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS 5. WIRES IN BATH LIGHT WELL. 6. NO WATER PRESSURE TEST ON PEX. 7. WIRES CANNOT BE EDGE NAILED (WEST OF LAUNDRY) | |
03/13/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. MISSSING ANCHOR BOLTS ON BOTTOM PLATES. 2. NO TEST ON PLUMBING. 3. LIGHT FIXTURE IN BATHROOM NOT PROPERLY INSTALLED. |