Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/20/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/19/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. SHEAR WALLS #3 REQUIRE A.B. AT 48" OC. AND BLOCKING AT TOP CONCERNED AREAS. 2. SW 3 BY FIREPLACE REQUIRES STUDS AT 16"O.C. AND A.B.'S. 3. FIRE PLACE HAS COMBUSTIBLE OSB USE CEMENT BOARD. 4. PEX NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS 5. WIRES IN BATH LIGHT WELL. 6. NO WATER PRESSURE TEST ON PEX. 7. WIRES CANNOT BE EDGE NAILED (WEST OF LAUNDRY) |
| 03/13/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. MISSSING ANCHOR BOLTS ON BOTTOM PLATES. 2. NO TEST ON PLUMBING. 3. LIGHT FIXTURE IN BATHROOM NOT PROPERLY INSTALLED. |