Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00CM06041

Parcel: 141112970


Addresses:

8500 E HODGMAN PL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM06041

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/10/2001 FRAMING Approved IVRS - Inspection 0000*
03/19/2001 FRAMING Partial Approval IVRS - Inspection 0000*
03/16/2001 FRAMING Denied IVRS - Inspection 0999*/1. ADD INSIDE STRAPS TO STAIRWELL BEAM POSTS. 2. DOUBLE TRIMMER UNDER MASTER PATIO HEADER. 3. BANG PLATE VENT ON UPSTAIRS OPTIONAL BATH TOP PLATE. 4. ONLY PARTIAL FRAME TILL ENG. APPROVED BY COT.