Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM06038
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/26/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/22/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. ISOLATE ROMEX CABLE NO BUNDLING AT ATTIC. 2. SECURE PEX LINES PER MANUF. SPECS OR 4' O.C. 3. DETAIL 15/SD3 NOT COMPLETE DETAIL 3/SD3 TRIPLE TRIMMERS AT 2 X 4 WALLS. 4. DETAIL 6/SD2 NOT COMPLETE. 5. PROVIDE 10 PSI FOR GAS LINE TEST. 6. SECURE 90 DEGREE VTR AT BOTTOM WITH APPROVED STRAPS P. TAPE NOT ACCEPTABLE. |