Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/28/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*OK WEST WALL |
| 06/14/2001 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*OK WALLS AND CEILING. |
| 06/12/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1. STAPLE ROMES WITHIN 12" OF BOXES. 2. SUPPORT ROMEX ABOVE PANEL.3. NEED FHA STRAP FOR PROTECTION ABOVE COLUMN 4. BOX OVER FILL - TO MANY/ CONDUCTORS - KITCHEN. 5. NEED ALL KITCHEN OUTLETS TO BE PROTECTED. 6. NEED OUTLET AT END OF ISLAND COUNTER. 7. FINISH LIGHT AT FRONT DOOR. 8. FINISH UPSTAIRS. 9. NEED BUSHING/CONNECTOR AT BOXES FOR LIGHTS. 10. OPEN EAST WALL FOR INSPECTION. |