Permit: T00CM06019

Parcel: 122183700


Addresses:

1415 N RICHEY BL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/11/2001 FRAMING Approved IVRS - Inspection 0000*
04/05/2001 FRAMING Partial Approval IVRS - Inspection 0000*/FRAME OK BUT CANNOT APPROVE UNTIL ELECT. IS INSTALLED.
04/02/2001 FRAMING Denied IVRS - Inspection 0999*/1. BATTEN ATTACHMENT BETWEEN STORAGE AND MODULAR HOME NOT ALLOWED (NO STRUCTURAL ATTACHMENT). 2. A POSTIVE UPLIFT ATTACHMENT IS REQUIED BETWEEN 6 X 8 BEAM AND 6 X 12 BEAM THAT IT IS BEARING ON. THERE ARE NO LISTED UPLIFT CALCULATIONS FOR 1/2" LAG BOLTS IN TENSION NOR WAS LAG BOLT INSPECTED. PROVIDE CITY OF TUCSON APPROVED DETAIL FOR ATTACHMENT. NOTE: I CANNOT APPROVE FRAME UNTIL ELECTRIC TRADE IS COMPLETE. OTHER THAN AS NOTED FRAME IS OK.
03/30/2001 FRAMING Denied IVRS - Inspection 0999*/1. BATTEN ATTACHMENT BETWEEN STORAGE AND HOUSE NOT ALLOWED SECURE BATTEN FROM STORAGE SIDE ONLY. 2. POSITIVE ATTACHMENT OF 6 X 8 BEAM TO 6 X 12 BEAM AT OVERLAP REQUIRED SUGGEST 2 EACH LSTA 9 STRAPS ONE EACH SIDE.