Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/12/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/09/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. FINISH NAILING OFF GLUE LAM BRACKET BETWEEN GARAGE DOORS AND EAST END. 2. PEX AGAINST FURNACE FLUE. 3. SHIM NORTH WINDOW HEADER, PATIO DOOR HEADER, ETC. ETC. 4. KITCHEN SINK SANITARY T CANNOT BE USED IN THE HORIZONTAL. 5. FINISH NAILING STUB TRUSS BRACKET OVER KITCHEN BAY WINDOW. 6. REPAIR SHEARWALL BEHIND 1ST FLOOR TUB. 7. PROVIDE TRUSS ENGINEER REPORT ON EXTRA LEDGER MATERIAL FOR STUB TRUSSES 8. GROUND METAL PANCAKE BOXES. 9. STRAP UPPER GABLE TOP PLATES AND SOUTHSIDE UPPER TOP PLATES. |