Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/15/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/04/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0920* 1.) 1935 ADDRESS MUST BE ON BUILDING IN 3" HIGH NUMBER MININUM 2.)GFCI WEATHER PROOF COVER LOOSE 3.) ALL OUTSIDE HOSE BIBS REQUIRE ANTI -SIPHON VALVES. 4.) AC DISCONNECT WORK AREA OSBTUCTED MUST HAVE 30 X 30 CLEAR AREA IN FRONT OF DISCONNECT. 5.) GAS LINE REQUIRE SHUT OFF VALVE UPSTREAM OF UNION. |
| 03/01/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*REF. REQUIRES SEPERATE CIRCUIT ON GFCI @ PRESENT GFCI & REF OUTLETS SWITCHED 3.) SECURE FLUE VENT @ W/H. 3.) TPRU DRAIN REQUIRES RIGID PIPE NOT PLEX PER CODE. |