Permit: T00CM05978

Parcel: 125160160


Addresses:

3624 E 5TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/20/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
03/19/2001 ELECTRIC - FINAL Denied 1. LABLE ALL CIRCUITS IN ELECTRICAL PANEL. 2. 1 1/2" CONDUIT NOT PROPERLY SECURED TO EXISTING ELECTRIC PANEL CONDUIT MUST MEET PANEL AT 90 DEGREE AND BE PROPERLY SECURED WITH ADDITIONAL WASHERS FOR EXCENTRIC KNOCK OUTS. ALSO REQUIRES ONE SECURITY CLAMP. 3. OUTSIDE ELECTRIC OUTLET MUST BE GFCI PROTECTED. 4. SINK AND COUNTERS NOT IN. 5. GFCI OUTLET WIRED INCORRECTLY. HOT WHEN TRIPPED. 6. ALL COUNTER OUTLETS MUST BE GFCI PROTECTOR.