Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 10/17/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 10/15/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0999*/ 1) MAIN HOUSE SEWER MUST HAVE CLEAN OUTS INSTALLED IN ORDER TO CLEAR ALL SEWER LINE 2) INSTALL CHECK VALVES AND UNIONS ON EJECTOR LINE PER INSTALLATION INSTRUCTIONS ALSO UNION ON VENT LINE |
| 10/11/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) LEFT DIAGRAM OF ELECTOR PLUMBING 2) YOU NEED A GATE VALVE ON 2' DISCHARGE LINE 3) DIRECTIONAL CLEANOUTS TO FACE SAME DIRECTION TOWARD HCS 4) NEED BACK FLOW PREVENTION AT OLD HOUSE 5) LEAVE ELECTOR INSTALLATION INSTRUCTIONS ON SITE 6) MAKE SURE KITCHEN DRAIN IS NOT CONNECTED TO ELECTOR VTR |
| 10/10/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NEED AN INSTALLATION SPECIFICATIONS FOR YOUR EJECTOR PUMP 2) WHAT ARE YOU DOING TO MAKE THE UNIT ACCESSIBLE 3) TWO INCH LINE COMING OUT OF THE NEW BLDG. HAS NO CLEANOUT, IT'S NOT SHOWN ON PLAN, WHAT IS IT? 4) CLEANOUTS ON 2" LINE FROM EJECTOR, THEY NEED TO BE INSTALLED FOR EASE OF MAINTENENCE, 5) YOU NEED A BACK FLOW PREVENTOR AT OLD HOUSE IF SEWER PLUGS UP AND EJECTOR PUMP TURNS ON YOU WILL PUMP SEWAGE INTO OLD HOUSE 6) PLEASE CLEAN UP YOUR PLANS, WASTED A LOT OF TIME TRYING TO FIGURE OUT THIS SITUATION |